Test Code C4 C4 (Fourth Component of Complement)
Performing Laboratory
Memorial Hospital Laboratory- Automated Procedures | 304-388-5953 |
Specimen Requirements
Serum- SST gold top, red top
Allow SST or red top to completely clot
Spin and physically separate serum from contact with cells as soon as possible
4 mL of serum (minimum 2 mL)
Specimen Rejection
- Improperly labeled, collected, stored, and transported
- Quantity not sufficient
Storage and Stability
Room temperature 15-30oC | 4 hrs |
Refrigerated 2-8oC | 8 days |
Frozen <-20oC | 3 months |
Reference Values
10 - 40 mg/dL
Methodology
Photometric assay
Days Test Set Up and Turnaround
Monday through Sunday, Continuously
AM Collection | Expected by 9AM same day |
Routine | Expected within 24 hrs |
Stat | Expected within 1 hr |
Timed | Expected results are test dependant |
CPT Coding
86160