Test Code DAT Poly Direct Antiglobulin Test, Blood
Performing Laboratory
Charleston Area Medical Center-Transfusion Services
Memorial | 304-388-4236 |
General | 304-388-6248 |
Women and Children's | 304-388-2380 |
Teays | 304-757-1770 |
Specimen Requirements and Processing
Draw 1 full 7 mL pink-top EDTA tube
Babies and small children- 1 plain pink-top EDTA microtainer
Note: Label specimen in indelible ink with patient’s full name, date of birth, hospital medical record number, date and time of draw, and initials of phlebotomist.
Special Instructions: Request form: CAMC LabWorks requisition, white Transfusion Services slip, or Gold Transfusion Services Envelope.
Specimen Rejection
- Improperly labeled, quantity not sufficient, hemolyzed and improper collection.
- Serum gel tube is not acceptable.
Storage and Stability
Specimen may be used for testing for 72 hours if sample is sufficient.
Methodology
Useful for detecting in vivo red cell sensitization and antibody and/or complement bound to patient’s red blood cells.
Reference Values
Negative (reported as positive or negative)
Alert value (automatic call-back): all positive cord blood or post-transfusion specimens
Days Test Set Up and Turnaround
Monday through Sunday, Continuously
CPT Coding
86880