Sign in →

Test Code MCLNR MayoComplete Lung Rearrangements, Rapid Test, Tumor


Ordering Guidance


Multiple oncology (cancer) gene panels are available. For more information see Hematology, Oncology, and Hereditary Test Selection Guide.



Necessary Information


Pathology report (final or preliminary) at minimum containing the following information must accompany specimen for testing to be performed:

1. Patient name

2. Block number-must be on all blocks, slides, and paperwork (can be handwritten on the paperwork)

3. Tissue collection date

4. Source of the tissue



Specimen Required


This assay requires at least 10% tumor nuclei.

-Preferred amount of tumor area with sufficient percent tumor nuclei: tissue 36 mm(2)

-Minimum amount of tumor area: tissue 18 mm(2)

-These amounts are cumulative over up to 10 unstained slides and must have adequate percent tumor nuclei.

-Tissue fixation: 10% neutral buffered formalin, not decalcified

 

Preferred:

Specimen Type: Tissue block and cell block

Collection Instructions: Submit a formalin-fixed, paraffin-embedded tissue block or cell block with acceptable amount of tumor tissue.

 

Acceptable

Specimen Type: Tissue slides

Slides: 1 Stained and 5 unstained

Collection Instructions: Submit 1 slide stained with hematoxylin and eosin and 5 unstained, nonbaked slides wit 5-micron thick sections of the tumor tissue.

Note: The total amount of required tumor nuclei can be obtained by scraping up to 5 slides from the same block.

Additional Information: Unused unstained slides will not be returned.

 

Specimen Type: Cytology slides (direct smears)

Slides: 1 to 3 Slides for smears

Collection Instructions: Submit 1 to 3 slides unstained or stained with Diff Quik or Pap and coverslipped with a preferred total of 5000 nucleated cells or a minimum of at least 3000 nucleated cells.

Note: Glass coverslips are preferred; plastic coverslips are acceptable but will result in longer turnaround times.

Additional Information: Cytology slides used in testing will have everything scraped and not be returned.


Useful For

Identifying lung tumors that may respond to targeted therapies by simultaneously assessing multiple genes involved in rearrangements resulting in fusion transcripts

 

Diagnosing and managing patients with lung cancer

Additional Tests

Test ID Reporting Name Available Separately Always Performed
SLIRV Slide Review in MG No Yes

Testing Algorithm

When this test is ordered, slide review will always be performed at an additional charge.

Method Name

Polymerase Chain Reaction (PCR)

Reporting Name

MayoComplete Lung Rearrangements

Specimen Type

Varies

Specimen Minimum Volume

See Specimen Required

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Ambient (preferred)
  Refrigerated 

Reference Values

An interpretive report will be provided.

Day(s) Performed

Monday through Friday

Report Available

4 to 8 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

81449

LOINC Code Information

Test ID Test Order Name Order LOINC Value
MCLNR MayoComplete Lung Rearrangements 73977-1

 

Result ID Test Result Name Result LOINC Value
618280 Result 82939-0
618281 Interpretation 69047-9
618282 Additional Information 48767-8
618283 Specimen 31208-2
618284 Tissue ID 80398-1
618285 Method 85069-3
618286 Disclaimer 62364-5
618287 Released By 18771-6