Test Code TBIL Bilirubin, Total
Performing Laboratory
Memorial Hospital Laboratory- Automated Procedures | 304-388-5953 |
General Hospital Laboratory | 304-388-6244 |
Women and Children's Hospital Laboratory | 304-388-2385 |
Teays Valley Hospital Laboratory | 304-757-1770 |
Cancer Center Laboratory | 304-388-8317 |
Plateau Medical Center Laboratory | 304-469-8621 |
Greenbrier Valley Laboratory | 304-647-6060 |
Specimen Requirements
Plasma- Mint Green, Dark Green Lithium Heparin or Serum- SST gold top, red top
Allow SST or red top to completely clot
Spin and physically separate plasma/serum from contact with cells as soon as possible
4 mL of plasma/serum (minimum 2 mL)
Specimen Rejection
- Improperly labeled, collected, stored, and transported
- Quantity not sufficient
Storage and Stability
Refrigerated 2-8oC | 3 days protected from light |
Frozen <-20oC | 3 months |
Reference Values
Reference Range
>18 yrs | 0.3-1.0 mg/dL |
>10-18 yrs | 0.2-1.2 mg/dL |
>2-10 yrs | 0.2-0.9 mg/dL |
>1 month-2 yrs | 0.2-2.2 mg/dL |
0- 1 month | 0.3-3.9 mg/dL |
Critical Pediatric Ranges
< 1 day | > 4.0 mg/dL |
> 1 day- 2 days | > 7.0 mg/dL |
>2 days- 3 days | > 9.0 mg/dL |
> 3 days- 4 days | > 11.0 mg/dL |
>4 days- 30 days | > 15.0 mg/dL |
> 30 days- 24 months | > 18.0 mg/dL |
Methodology
Photometric Diazonium salt 3,5 DPD | Memorial, General, Women and Children's, Teays, Cancer Center, Plateau |
End Point Colorimetric (dual wavelength) | Greenbrier |
Days Test Set Up and Turnaround
Monday through Sunday, Continuously
AM Collection | Expected by 9AM same day |
Routine | Expected within 24 hrs |
Stat | Expected within 1 hr |
Timed | Expected results are test dependant |
CPT Coding
82247