Test Code VIT B12 Vitamin B12 Assay
Performing Laboratory
Memorial Hospital Laboratory- Automated Procedures | 304-388-5953 |
Teays Valley Hospital Laboratory | 304-757-1770 |
Greenbrier Valley Laboratory | 304-647-6060 |
Parkersburg Laboratory | 304-865-3679 |
Beckley Cancer Center Laboratory | 304-461-2222 |
Specimen Requirements
Plasma- Mint Green, Dark Green Lithium Heparin or Serum- SST gold top, red top
Allow SST or red top to completely clot
Spin and physically separate plasma/serum from contact with cells as soon as possible
4 mL of plasma/serum (minimum 2 mL)
Additional sample type that can be used ONLY at Greenbrier, Beckley and Parkersburg
EDTA plasma
Specimen Rejection
- Improperly labeled, collected, stored, and transported
- Quantity not sufficient
- Hemolyzed
Additional rejections ONLY at Greenbrier, Beckley, and Parkersburg
- Turbid
- Lipemic
Storage and Stability
Memorial and Teays Only
Room temperature 15-30oC | 8 hrs |
Refrigerated 2-8oC | 24 hrs |
Frozen <-20oC | Not specified |
Greenbrier, Beckley, Parkersburg Only
Refrigerated 2-8oC | 7 days |
Frozen <-20oC | 4 weeks |
Avoid repeated freeze-thaw cycles.
Reference Values
180.0-914.0 pg/mL
Methodology
Memorial and Teays | Chemiluminescent immunoenzymatic competitive assay |
Greenbrier, Beckley, Parkersburg | Competitive binding immunoassay |
Days Test Set Up and Turnaround
Memorial, Teays, Greenbrier-Monday through Sunday, Continuously
Beckley, Parkersburg-Monday through Friday
AM Collection | Expected by 9AM same day |
Routine | Expected within 24 hrs |
Stat | Expected within 1 hr |
Timed | Expected results are test dependant |
CPT Coding
82607